Query helper

A query helper is a small standalone script that connects to a real device, reads it once, and dumps every value to the terminal. It’s the single most useful tool when bringing up a new device library — you can check a physical controller without any application around it.

You don’t have to hand-roll the plumbing. The library ships the building blocks in modbus_connection.cli_helper, so a query script imports the pieces it needs instead of re-implementing argument parsing, connection setup, read counting and value printing every time:

Building block What it does
add_connection_args(parser, connections=…) Add the connection arguments (target, transport, framer, port, timeout, serial/TLS options) to an argparse parser.
connect_from_args(args, *, message_spacing=0.0) Open the connection those arguments describe (over whichever backend is installed).
CountingUnit Wrap a ModbusUnit to count the block reads an update performs.
print_component(component, *, title=None, file=None) Print every field on a component by reflection.
field_rows(component) The (name, value) rows behind print_component, if you want to format them yourself.

That’s the whole thing — parse, connect, wrap, read, print:

import argparse
import asyncio
from modbus_connection import ModbusError
from modbus_connection.cli_helper import (
CountingUnit,
add_connection_args,
connect_from_args,
print_component,
)
from my_device import MyDevice # your modelled Component / device entrypoint
async def main() -> int:
parser = argparse.ArgumentParser(description="Query a device and print values.")
add_connection_args(parser)
# The unit id is not part of connecting — it varies per device and per tool —
# so add whatever the CLI needs alongside the connection arguments.
parser.add_argument("--unit", type=int, default=1, help="Modbus unit id")
args = parser.parse_args()
try:
conn = await connect_from_args(args)
except ModbusError as err:
print(f"Could not connect: {err}")
return 1
counting = CountingUnit(conn.for_unit(args.unit))
try:
device = MyDevice(counting)
await device.async_update()
finally:
await conn.close()
print_component(device)
print(f"\n{counting.reads} Modbus reads")
return 0
raise SystemExit(asyncio.run(main()))

Run it against a device — add_connection_args gives you a full connection CLI for free:

Terminal window
python query.py 192.168.1.50 --unit 246 --framer rtu
python query.py /dev/ttyUSB0 --transport serial --unit 246 --baudrate 19200
python query.py --help # works without a backend installed

The machine running the query helper doesn’t need a serial port of its own. An ESPHome device running the serial_proxy component exposes a UART over its native API, so a Modbus device wired to the ESP is reachable over the network. Point the serial transport at it with an esphome:// URL in place of a device path — nothing else about the script changes:

Terminal window
python query.py "esphome://basement.local/?port_name=modbus" \
--transport serial --unit 246 --baudrate 19200

The URL is just the connection target, so the serial options carry through to the ESP’s UART — --baudrate / --parity / --stopbits are applied remotely by the proxy. RTU is the serial default, so no --framer is needed.

URL formatesphome://<host>[:<port>]/?port_name=<name>, where <port> defaults to 6053 (the ESPHome API port) and <name> is the serial_proxy instance’s name. For an encrypted or password-protected device, add a noise_psk= (or password=) query parameter. A device with a single unnamed proxy also accepts the numeric form esphome://<host>/<instance>.

Adds the connection-specifying arguments in their own “Modbus connection” group (plus serial and TLS groups when those transports are offered), so they read as a block in --help and stay clear of your CLI’s own options — like the --unit you add yourself.

By default it offers every transport and framing. Pass connections= the (transport, framer) pairs your device actually supports and the CLI narrows to match — a device that only speaks RTU-over-TCP needs no serial, TLS, --transport or --framer clutter:

# Only RTU-over-TCP: no --transport flag, --framer fixed to rtu, no serial/TLS args.
add_connection_args(parser, connections=(("tcp", "rtu"),))

A None framer means the backend default (and is required for TLS). The parser it produces is read back by connect_from_args, so the two always stay in step.

Opens the connection the parsed arguments describe, dispatching to connect_tcp / connect_udp / connect_tls / connect_serial on whichever backend is installed — tmodbus first, then pymodbus (resolved lazily, so importing the module needs no backend). Pass message_spacing= for a device that needs a gap between frames — it’s a fixed device property, so the tool sets it rather than exposing it as a CLI argument:

conn = await connect_from_args(args, message_spacing=0.1)

It raises ModbusError if no backend is installed, ModbusConnectionError if the link can’t be opened, and NotImplementedError for --transport udp on tmodbus (it has no UDP transport — install pymodbus, which does, if you need it).

Wrap connection.for_unit(id) in a CountingUnit before handing it to a component. Its reads attribute then tallies every block read the update issued — a quick sanity check that your ranges and max_gap are collapsing fields into as few Modbus round-trips as the plan allows. It implements ModbusUnit in full, so it drops in wherever one is expected with no cast:

counting = CountingUnit(conn.for_unit(args.unit))
device = MyDevice(counting)
await device.async_update()
print(counting.reads) # e.g. 6

print_component walks a component’s public attributes by reflection and prints each modelled field — register/coil/discrete fields and computed @property values — under a heading, values aligned, with each field’s unit appended. A new field shows up with no change to the script. Read the component first; unread fields render as :

print_component(device.sensors, title="Sensors")

If you want to format the output yourself (JSON, a table, grouping by section), field_rows(component) returns the (name, value) rows and you take it from there.

Sensors
-------
outside_1 4.2 °C
flow_1 58.1 °C
return_1 41.0 °C
6 Modbus reads

The read count is the payoff of pooled planning — dozens of fields read in a handful of Modbus round-trips. If you model your device as a ComponentGroup, loop over its components and print_component each one.